HDL cholesterol performance using an ultracentrifugation reference measurement procedure and the designated comparison method
Nakamura M , Yokoyama S , Kayamori Y , Iso H , Kitamura A , Okamura T , Kiyama M , Noda H , Nishimura K , Nakai M , Koyama I , Dasti M , Vesper HW , Teramoto T , Miyamoto Y . Clin Chim Acta 2015 439 185-90 BACKGROUND: Accurate high-density lipoprotein cholesterol (HDL-C) measurements are important for management of cardiovascular diseases. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform ultracentrifugation (UC) reference measurement procedure (RMP) to value assign HDL-C. Japanese CRMLN laboratory (Osaka) concurrently runs UC procedure and the designated comparison method (DCM). Osaka performance of UC and DCM was examined and compared with CDC RMP. METHODS: CDC RMP involved UC, heparin-MnClâ‚‚ precipitation, and cholesterol analysis. CRMLN DCM for samples containing <200 mg/dl triglycerides involved 50-kDa dextran sulfate-MgCl2 precipitation and cholesterol determination. RESULTS: HDL-C regression equations obtained with CDC (x) and Osaka (y) were y=0.992x+0.542 (R(2)=0.996) for Osaka UC and y=1.004x-0.181 (R(2)=0.998) for DCM. Pass rates within ±1 mg/dl of the CDC target value were 91.9 and 92.1% for Osaka UC and DCM, respectively. Biases at 40 mg/dl HDL-C were +0.22 and -0.02 mg/dl for Osaka UC and DCM, respectively. CONCLUSIONS: Osaka UC and DCM were highly accurate, precise, and stable for many years, assisting manufacturers to calibrate products for clinical laboratories to accurately measure HDL-C for patients, calculate non-HDL-C, and estimate low-density lipoprotein cholesterol with the Friedewald equation. |
Total cholesterol performance of Abell-Levy-Brodie-Kendall reference measurement procedure: certification of Japanese in-vitro diagnostic assay manufacturers through CDC's Cholesterol Reference Method Laboratory Network
Nakamura M , Iso H , Kitamura A , Imano H , Kiyama M , Yokoyama S , Kayamori Y , Koyama I , Nishimura K , Nakai M , Dasti M , Vesper HW , Miyamoto Y . Clin Chim Acta 2015 445 127-32 BACKGROUND: Accurate measurement of total cholesterol (TC) is important for cardiovascular disease risk management. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform Abell-Levy-Brodie-Kendall (AK) reference measurement procedure (RMP) for TC as a secondary reference method, and implement Certification Protocol for Manufacturers. Japanese CRMLN laboratory at Osaka performed the AK RMP for 22 years, and conducted TC certification for reagent/calibrator/instrument systems of six Japanese manufacturers every 2 years for 16 years. Osaka TC performance was examined and compared to CDC's reference values. METHODS: AK RMP involved sample hydrolysis, cholesterol extraction, and determination of cholesterol levels by spectrophotometry. The Certification Protocol for Manufacturers includes comparison with AK RMP using at least 40 fresh specimens. Demonstration of average bias ≤3% and total coefficient of variation ≤3% qualified an analytical system for certification. RESULTS: In the AK RMP used in the Osaka CRMLN laboratory, the regression equation for measuring TC was y (Osaka)=1.000x (CDC)+0.032 (n=619, R2=1.000). Six Japanese manufacturers had allowable performance for certification. CONCLUSIONS: The AK RMP for TC measurement was accurate, precise, and stable for 22 years. Six Japanese manufacturers were certified for 16years. |
LDL cholesterol performance of beta quantification reference measurement procedure
Nakamura M , Kayamori Y , Iso H , Kitamura A , Kiyama M , Koyama I , Nishimura K , Nakai M , Noda H , Dasti M , Vesper HW , Miyamoto Y . Clin Chim Acta 2014 431 288-93 BACKGROUND: Accurate measurement of blood lipids is crucial in cardiovascular disease risk management. The Centers for Disease Control and Prevention (CDC) Cholesterol Reference Method Laboratory Network (CRMLN) has assured the accuracy of these measurements for >20 y using beta quantification (BQ) method as reference measurement procedure (RMP) for high- and low-density lipoprotein cholesterol (HDL-C, LDL-C). Only limited data exist about the performance of the BQ RMP. METHODS: Bottom fraction cholesterol (BFC), HDL-C, and LDL-C results after ultracentrifugation from the CDC lipid reference laboratory and the Japanese CRMLN laboratory were compared using 280 serum samples measured over the past 15 y. Data were compared statistically using method comparison and bias estimation analysis. RESULTS: Regression analysis between CDC (x) and Osaka (y) for BFC, HDL-C, and LDL-C were y=0.988x+1.794 (R2=0.997), y=0.980x+1.118 (R2=0.994), and y=0.987x+1.200 (R2=0.997), respectively. The Osaka laboratory met performance goals for 90% to 95% of the CDC reference values. CONCLUSIONS: The BQ method by the Osaka CRMLN laboratory is highly accurate and has been stable for over 15 years. Accurate measurement of BFC is critical for determination of LDL-C. |